首页    溶剂清洗和汽相清洗剂    科慕Vertrel™ XP 10清洗剂
1606283386-1

科慕Vertrel™ XP 10清洗剂

Vertrel™ XP 10

Vertrel™ X-P10 specialty fluid


 Vertrel™  X-P10 specialty fluid is a special solvent blend of Vertrel™  XF and isopropanol. It is specially designed to improve solvency for polar solids.


Applications

Vertrel™  X-P10 is widely used for the following applications:
Carrier Fluid/Lubricant Deposition
Drying/Rinsing Agent
Light Soil Removal


Compatibility and Soils

Vertrel™ X-P10 specialty fluid is compatible with most plastics and elastomers. Vertrel™ X-P10 can be used to clean a wide variety of soils including flux residue, cutting oils, gear oils, heavy greases, hydraulic oils, stamping oils, synthetic oils, vacuum oils, waxes, and mineral oils.


Environmental Properties

Vertrel™  has zero ozone-depletion potential. It is used extensively to replace CFC-113, methyl chloroform, hydrochlorofluorocarbons (HCFCs), and perfluorocarbons (PFCs) in several applications.
Vertrel™ X-P10 has been accepted by the U.S. Environmental Protection Agency (EPA) under the Significant New Alternatives Policy (SNAP) program, as a substitute for ozone-depleting substances. Vertrel™  X-P10 is not a hazardous air pollutant (HAP) and, therefore, not subject to NESHAP regulations. Spent Vertrel™  X-P10 is not an RCRA characteristic or listed waste. However, addition of contaminants could change that status. Vertrel™ X-P10 is not included in the SARA Title III Section 313 list of toxic chemicals, and is not subject to SARA Title III (EPCRA) reporting requirements.
The components of Vertrel™  X-P10 are listed in the TSCA inventory. One component, HFC-43-10mee, is subject to the Significant New Use Rule (SNUR) and should be used only in the applications indicated in the Vertrel™  X-P10 MSDS regulatory section.


Flammability and Toxicity

Vertrel™  X-P10 specialty fluid exhibits no closed-cup flash point in accordance with the Tag Closed Cup Tester (ASTM D-56) and is not classified as a flammable liquid by NFPA or DOT. However, the product does exhibit vapor flammability limits in air. Users should clear equipment of all vapors and liquids before performing any maintenance operations that may result in an ignition source.
Flash point data and limits of flammability in air provide the user with additional information that should be used as elements of a fire risk assessment and to determine guidelines for safe handling of volatile chemicals. Users should ensure compliance with NFPA standards and local fire codes.
Acute toxicity studies show that Vertrel  X-P10 has low toxicity. It is a slight skin and eye irritant and has low inhalation toxicity. For exposure limits, please refer to the Vertrel  X-P10 brochure.

 

专为极性溶解设计的特殊溶剂混合物

Vertrel™ X-P10 特种氟化液是旨在提高极性固体的溶解能力。

Vertrel™ X-P10 与大多数塑料和弹性体相容。典型应用包括吸收干燥以及精密和特殊清洗和冲洗,可去除塑料、玻璃和金属部件上的颗粒轻质污垢和指纹。

功能和优点

功能多样和极其有效的 Vertrel™ X-P10 具有各种关键功能,包括:

  • 高密度、低粘度和低表面张力,可清洗难以触及的狭窄区域

  • 适合干燥和清洗颗粒物质

  • 臭氧消耗潜值接近零

  • 可在众多应用中替代 CFC-113, 1,1,1-三氯乙烷 (1,1,1-TCA)、氢氯氟烃 (HCFC) 和多氟烷烃 (PFC)